About 81 results
Open links in new tab
  1. Laundry room drains - washer and sink on same drain with AAV

    Nov 20, 2022 · The bathroom downsteam will be vented temporarily with an aav, and then when renovations are continued next year on the upstairs bathroom, venting will be tied into the main vent …

  2. Any disadvantages to using an AAV - Love Plumbing & Remodel

    Dec 8, 2022 · An AAV only works with negative pressure, no positive pressures. A vent through the roof does both. In fact a vent through the roof is needed somewhere in the system for an AAV to function …

  3. Installing an AAV under kitchen sink with a S-Trap.

    Apr 13, 2025 · Discussion on installing an air admittance valve (AAV) under a kitchen sink with an S-trap, addressing code compliance and practical considerations.

  4. Stumped by vent issue with AAV in new bathroom

    Dec 5, 2016 · An AAV ONLY allows air in, and if there is a positive pressure, which it can do nothing to eliminate, the drains will not function. Nope - just tested it as per Reach4's suggestion, with the AAV …

  5. AAV On Sink /Wet Vent for Toilet? With Diagram

    Feb 4, 2013 · An AAV only lets air in. With it in that location, when you flushed the toilet, there's a pressure wave in front of the wave as the stuff flows down the pipe. That would want to push stuff to …

  6. AAV for a island sink - The Building Code Forum

    Jul 22, 2022 · Backsplash to get the vent high enough. So Is it possible to vent the island sink that also has a dishwasher and disposal by using a AAV mounted as high up as possible. Or I’m a stuck with …

  7. Double Vanity with AAV - Love Plumbing & Remodel

    Dec 8, 2019 · To properly plumb the double vanity, am I allowed to use two AAV, one at each p-trapped sink? See attached drawing. Both branch arms will connect to the existing jacuzzi 1.5” drain that then …

  8. AAV question - The Building Code Forum

    Jul 2, 2014 · SFR in California, full kitchen remodel. The kitchen sink used to have a wall behind it that contained the vent line. New plan call for the sink to be on a peninsula, same location, so the drain …

  9. Is bypassing my roof vent stack with AAV's acceptable?

    Feb 1, 2019 · · Install air admittance valve (AAV) in the attic on the 2” pvc vent stack (where the bathroom vent stack meets the flat run in the attic. · Install air admittance valve in the vanity for the …

  10. Venting a shower with an AAV - Love Plumbing & Remodel

    Aug 8, 2013 · I'm plumbing a new bathroom in an old house. A really old house. And since it's made of brick and plaster I decided to vent using AAVs instead of tearing up plaster walls and ceilings to get …